RG59 Armoured Coaxial Cable
    Applications 
   These 75Ω coaxial cables are suitable for installation on board of ships and   other indoor marine environments.
   Standards
      
         
           
             | IEC 60092-350 | IEC 60332-3-22 | 
           
             | IEC 60754-1,2 | IEC 61034-1,2 | 
           
             | NEK 606:2004 |  | 
         
                  
         
    
   
   Construction
   
     - Conductors : 20AWG solid bare copper. 
- Insulation : Foam PE. 
- Shielding1 : Al/Polyester/Al tape. 
- Shielding2 : Tinned copper braid. 
- Bedding : Low smoke and halogen-free polyolefin,   coloured black. 
- Armour : Tinned Copper wire braid. 
- Outer Sheath : Low smoke and halogen-free   polyolefin. 
Electrical Characteristics
   
      
     
       | AWG |  | 20 | 
     
       | Nominal Conductor Diameter | mm | 0.8 | 
     
       | Impedance | Ω | 75+/-5 | 
     
       | Nominal Attenuation@100MHz | dB/100m | 7.6 | 
     
       | Nominal Attenuation@270MHz | dB/100m | 12.5 | 
     
       | Nominal Attenuation@540MHz | dB/100m | 17.9 | 
     
       | Nominal Attenuation@720MHz | dB/100m | 20.9 | 
     
       | Nominal Attenuation@750MHz | dB/100m | 21.3 | 
     
       | Nominal Attenuation@1000MHz | dB/100m | 24.9 | 
     
       | Capacitance | pF/m | 53.5 | 
     
       | Velocity of Propagation | % | 83 | 
     
       | Conductor DCR | Ω/km | 32.8 | 
     
       | Shield DCR | Ω/km | 12.5 | 
     
       | Inductance | μH/m | 0.318 | 
     
       | Time Delay | ns/m | 4.0 | 
    
   
   Mechanical and Thermal Properties
   
     - Bending Radius : 15×OD. 
- Temperature Range : -30℃ ~ +75℃. 
Dimensions and Weight
   
     
       
         | Nominal Inner Conductor Diameter mm | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km | 
       
         | 0.8 | 1.4 | 1.2 | 10.0 | 177 |